Connex Integrated Wall Vital Signs System - wall-mounted - touchscreen

SKU: 4MD-36363

$9,271.38

  • Large, easy-to-read, color touchscreen
  • Capture pulse oximetry with Masimo or Nellcor SpO2 sensors
  • Connect to Detecto or Health o meter scales
  • Connect to your EMR via Wi-Fi or Ethernet
  • Select from SureTemp Plus and/or Braun ThermoScan PRO 6000 thermometry
  • Quickly and securely access a device with single sign-on (including RFID Scanner Imprivata integration)
  • Help identify signs of patient deterioration with automated Early Warning Scores
  • Customize your workflow to document patient observations and vitals modifiers

-

  • Net-30 terms & POs accepted
  • Government & GSA purchasing
  • Volume & contract pricing
  • Tax-exempt ordering

One convenient, comprehensive physical assessment and vital signs monitoring solution. The all-in-one design helps simplify workflows. The Connex Integrated Wall System provides vital tools to help you quickly examine patients and support decision making with complete, accurate information.

Features
  • Large, easy-to-read, color touchscreen
  • Capture pulse oximetry with Masimo or Nellcor SpO2 sensors
  • Connect to Detecto or Health o meter scales
  • Connect to your EMR via Wi-Fi or Ethernet
  • Select from SureTemp Plus and/or Braun ThermoScan PRO 6000 thermometry
  • Quickly and securely access a device with single sign-on (including RFID Scanner Imprivata integration)
  • Help identify signs of patient deterioration with automated Early Warning Scores
  • Customize your workflow to document patient observations and vitals modifiers
Cuff Inflation Target Adult160 mmHg; Pediatric: 140 mmHg; Neonate: 90 mmHg
Systolic Range Adult/Pediatric30 – 260 mmHg; Neonate: 20 – 120 mmHg
Diastolic Range Adult/Pediatric20 – 220 mmHg; Neonate: 10 – 110 mmHg
MAP Range Adult/Pediatric23 – 230 mmHg; Neonate: 13 – 110 mmHg
Blood Pressure AccuracyMeets the ANSI/AAMI SP10:2002 and ISO/ANSI/AAMI 81060-2:2013 standards for noninvasive blood pressure accuracy (±5 mmHg mean error, 8 mmHg SD)
BP Determination Time15 seconds typical, 150 seconds max
Overpressure Cutoff Adult/Pediatric300 mmHg ± 15 mmHg; Neonate: 150 mmHg maximum
Pulse Rate Range Adult/Pediatric30 – 200 bpm; Neonate: 35 – 220 bpm
Pulse Rate Accuracy± 5.0% ( 3 bpm)
Measurement Range SureTemp Plus80 – 110°F (26.7 – 43.3°C); Braun: 68 – 108°F (20 – 42.2°C)
Calibration Accuracy SureTemp Plus±0.2°F (±0.1°C)
Braun±0.4°F (for temps up to 107.6°F), ±0.5°F (for temps higher than 107.6°F)
OralApproximately 4-6 seconds
Adult Axillary (18 years and older)Approximately 15 seconds
Pediatric Axillary (17 years and younger)Approximately 10 seconds
RectalApproximately 10 seconds
TympanicApproximately 3 seconds
Measurement Range1 – 100%
Pulse Rate Range Masimo25 – 240 bpm; Nellcor: 25 – 240 bpm; Nonin: 40 – 240 bpm
SpO2 Accuracy Masimo± 2 digits; Nellcor: ± 3 digits; Nonin: ± 3 digits
Pulse Rate Accuracy Masimo± 3 digits; Nellcor: ± 3 digits; Nonin: ± 3 digits
OralApproximately 4-6 seconds
Adult Axillary (18 years and older)Approximately 15 seconds
Pediatric Axillary (17 years and younger)Approximately 10 seconds
RectalApproximately 10 seconds
TympanicApproximately 3 seconds
  • Connex Integrated Wall System with Masimo SpO2
  • SureTemp Plus Thermometry
  • Braun ThermoScan PRO 6000 Thermometry
  • BP Cuff and Cord Management System
  • Integrated MacroView Plus LED Otoscope for iExaminer
  • PanOptic Plus LED Ophthalmoscope
California Prop 65

WARNING: This product can expose you to chemicals including arsenic, which is known to the State of California to cause cancer. For more information, visit Proposition 65